| Code | Description | Explanation | Resolution |
|---|---|---|---|
| 1 | Gain Fault | Output power is lower than expected with given input power | Re-tune amp or reduce drive power |
![]() | |||
| 2 | Mains Board could not find a tap to match line voltage | AC mains are Fluctuating too much or amp was not given 30 seconds for the detection circuit to stabilize | Allow amp mains circuit to stabilize before powering back on. Or, force amp to use a fixed tap. |
![]() | |||
| 3 | Soft Ip fault trip | Plate current above 1.5 amps. | Reduce drive or re-tune |
![]() | |||
| 4 | Hard Ip fault trip | Plate current above 2 amps. | Reduce drive or re-tune |
![]() | |||
| 5 | Vp did not reach specified value in specified time | High Voltage did not reach 3500 volts in specified time. | Check transformer connections and AC mains connections. Check that auto tap selection is enabled or that amp is correctly reading ac line voltage. |
![]() | |||
| 6 | Output relay did not close in time | Output T/R relay did not close. | Amplifier is in operate and no key line detected. Check Key line by shorting center conductor to screw on amp. Use the Transceiver side for this test. |
![]() | |||
| 7 | Output relay apparently stuck on | Amplifier is keyed with no key line connected. | You should not see this fault in the field. |
![]() | |||
| 8 | Bandswitch failed to reach target setting | Bandswitch failed to move during power up. | Turn the amp off and back on. If the fault does not clear. Turn the amp off and unplug it from the AC Mains. Plug the amp back in and power up once more. If fault still does not clear. While the amp is on press a bandswitch on the front of the amp and fault should clear. |
![]() | |||
| 9 | Tune cap could not locate zero | Cap needs to be re-initialized | Turn the amp off and back on. |
![]() | |||
| 10 | Load cap could not locate zero | Cap needs to be re-initialized | Turn the amp off and back on. |
![]() | |||
| 11 | Temperature fault | Tube deck reached a temp of 45 deg C. | Check air flow from behind and over the amplifier. Check tubes for blockage. Fault will clear when the amp temperature is within limits. |
![]() | |||
| 12 | Reflected power trip | SWR above 3:1 | Check antennas and other equipment installed after the amplifier. |
![]() | |||
| 13 | Clear temperature fault | Amp had faulted for a fault 11 and recovered. | See fault 11 |
![]() | |||
| 14 | Plate voltage too high | Plate voltage above 3800 Vdc. | Check AC mains voltage. Unplug amp and plug amp back in and allow 30 seconds before turning back on. Check that auto tap selection is enabled, or that correct fixed tap has been forced. |
![]() | |||
| 15 | Grid current trip | Grid current above 150 mA | Reduce drive or retune |
![]() | |||
| 16 | Auto-tune algorithm failed to resolve | Auto tune was unable to find a good tune point given the input power. | Reduce drive and re-start the auto tune. |
![]() | |||
| 17 | Plate current too high with amp unkeyed | Amplifier has been turned on and the plate current in idle is too high with no RF drive and amp unkeyed | Tube may be shorted or HV Circuit is not functioning correctly |
![]() | |||
| 18 | Input power greater than 100W | Enough said! | |
![]() | |||