All amateur bands 1.8-29.7 MHz* plus extensive out-of-band. *24-30 MHz lockout easily de-activated by authorized owners.
1.5 kW PEP or carrier, any mode, no time limit 50-60 W nominal for full rated output. < 1.5:1 within amateur bands, < 2:1 outside. More than 50 dB below PEP output. More than 40 dB below PEP output.
Automatic trips for excessive drive, load mismatch, average grid or plate current; also for RF arc, severe mistuning, or improper T/R sequencing. Peak grid limiting, primary fuses, cover interlock & HV crowbar. AC inrush-current limiting (Step-start).
Full-cabinet forced air; blower mounted on foam "sandwich" to absorb noise and vibration. Thermostatic fan option for continuous duty at maximum average power.
Grid current derived, O to -1OV maximum. 200-240V, 50-60 Hz, 1 phase, 20A maximum. 17.3" W x 7" H x 16.5" D (439 x 178 x 419 mm); 65 lb. (30 kg). Removable plug-in transformer; UPS shippable.
|